Table 1

Comparison of sampling techniques for different coagulation parameters: Vena cava puncture (VCP) vs tail cut (TC) as measured by Prothrombin Time (PT) and activated Partial Thromboplastin Time (aPTT) in plasma of untreated negative control mice

Assay:
PT mean (SD)
aPTT mean (SD)
number of samples not evaluable
number of samples analyzed
% of samples not evaluable

Sampling technique:
[s]
[% of standard]*
[s]
[n]
[n]
[%]








VCP 1:5
9.2 (1.0)
94 (10)
31.7 (4.6)
3
15
20%
VCP 1:10
7.8 (0.1)
116 (13)
23.2 (0.8)
0
10
0%
TC 1:5
-
-
-
3
3
100 %
TC 1:10
-
-
-
4
4
100 %







Ref.values:
8–10
80–120
32–36/23–25†




* where the clotting time of a normal plasma standard was defined as 100%

† normal values depended on citrate:blood ratio, and were 32–36 s for 1:5 ratio and 23–25 s for 1:10 ratio

Unruh et al. Thrombosis Journal 2005 3:21   doi:10.1186/1477-9560-3-21